ZT4211 PXI
Lecroy PXD222 Replacement Solution
The ZTEC ZT4211 PXI is a modern
oscilloscope that provides extensive functionality, in most cases beyond that of the PXD222.
See below for a list of the differences between the ZT4211 and the PXD222. Because the instrument functionality, command set, and I/O
ranges are different, there is some effort involved with the integration of the ZT4211 in place of the PXD222.
ZTEC's application engineering team has significant experience with the functional differences between the PXD222
and the ZT4211, as well as the application details of using oscilloscopes in ATE test programs. This experience
is invaluable when assisting a test system integrator in successfully modifying an existing ATE system or TPS.
Please, visit the ZTEC ZT4210 Series
page for more information on the ZT4211.
| Specification | PXD222 | ZT4211PXI |
|---|---|---|
| Input Channels | 2 | 2 (ZT4211)
or 4 (ZT4212: VXI/LXI only) |
| Platform & Size | 2 slot 3U PXI | Single-Wide 3U PXI
(PCI, VXI, & LXI available) |
| Digitizer Resolution | 8 bits | 8 bits |
| Input Bandwidth | 200 MHz (-3 dB) | 300 MHz |
| Input Coupling | DC, AC | DC, AC |
| Input Filter | Not supported | 20 MHz or Bypass
Filter Stopband Rejection: approximately 3dB @ 20 MHz |
| Input Impedance | 1MΩ(±1%)//15 pF (±2 pF) | 1MΩ(±1%) || 12 pF or 50Ω |
| Maximum Input | direct(1:1) 300 V CAT II
with 10:1 probe 1000V |
50Ω: ±5 V (DC + peak AC), CAT II Input load protection @ ±6 VDC 1MΩ: ±300 V [DC + peak AC (<100 kHz)], CAT II Peak AC, de-rated 20 dB/decade above 100 kHz |
| Sample Rate | Glitch Capture Mode: up to 2.5 GS/s
Scope Record Mode: up to 20 MS/s |
10 kS/s to 500 MS/s real-time,
1 GS/s Interleaved to 100 GS/s Interleaved Equivalent Time |
| Maximum Record Length | Glitch Capture Mode: 250 points
Scope Record Mode: 27K points (up to 20 MS/s) |
128 MiSamples or 256 MiSamples Interleaved |
| Trigger Modes | Edge, Video & Pulse Width
Video: PAL, PAL+, NTSC, SECAM, Filed 1 or Field 2, Line Select |
Edge, Pattern, State, Pulse Width, Video
Video: PAL (50 Hz), NTSC (60 Hz), SECAM (50 Hz) Standard, Field, Line selectable |
| Pre-Trigger Capture | 90% of the recorded time | 0 to 100% of acquisition window |
| Trigger Sources | Ch1,Ch2,PXI_TRIG[n],PXI_STAR[n] | Channels 1 to 2, Channels 3 to 4 (ZT4212), External Input, Pattern, Software, TTL Trigger 0-7, Star Trigger (PXI/PCI), ECL Trigger 0-1 (VXI) |
| Trigger Holdoff Range | Up to 100 times the recorded span time
Maximum Delay: 10 seconds |
Programmable Delay: 0 to 100 seconds |
| Arm | Not supported | Trigger qualifier |
| Clock Accuracy | ± 100 ppm | < 2.5 ppm |
| External Out | Not supported | Trigger Out, 10 MHz, Event Out,
Probe Compensation, Programmable Clock/Pulse |
| Power | +5 VDC 1.6 A (8 W) | 2 Channels PXI:
Typical 17.0 W Max. 24.0 W |
Get your questions answered thoroughly and quickly by submitting a ticket to the ZTEC Customer Support Center.